High disk usage notifications were sent every ~10 minutes on Coolify Cloud
because the cache rate limiter did not hold across Sentinel-triggered checks.
- Add a notification_throttles table and NotificationThrottle helper that
atomically records when a notification was sent for a resource.
- Add the ThrottledNotification contract; Team::notify() skips a throttled
notification that was already sent within its interval.
- High disk usage: configurable per-server interval
(server_disk_usage_notification_interval_hours, default 24h) in
Server > Advanced and the servers API.
- Container restarted (coolify-proxy, database TCP proxy): at most one
notification per hour per server/database during a restart loop.
- Move the unreachable and missing-backup markers into the new table and
migrate existing data (servers.unreachable_notification_sent and
scheduled_database_backups.missing_backup_notification_sent_at).
- Regenerate OpenAPI files.
- Delete Blade components, component classes, Livewire components and
views that nothing uses after the redesign.
- Delete tests that only compare Blade/CSS source text; keep the source
checks for authorization gates, stable wire:key values and escaping.
- Update stale tests to the current UI and behaviour.
- Update DESIGN.md to the current navigation and layout.
- Add a lesson: test behaviour, not source markup.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Set unreachable_count to 3 and unreachable_notification_sent to true
on all team servers in subscriptionEnded(), so the existing cleanup
command can pick them up after the 7-day grace period.
Also adds feature tests for the subscription-ended cleanup flow and
casts server IP to string in existing unreachable server tests to fix
type comparison.