"""Tests for the Fronius Modbus control switches."""
|
|
|
|
from unittest.mock import patch
|
|
|
|
from fronius_modbus.testing import build_sunspec_map
|
|
from modbus_connection import IllegalDataValueError
|
|
from modbus_connection.mock import MockModbusConnection
|
|
import pytest
|
|
|
|
from homeassistant.components.switch import DOMAIN as SWITCH_DOMAIN
|
|
from homeassistant.const import (
|
|
ATTR_ENTITY_ID,
|
|
SERVICE_TURN_OFF,
|
|
SERVICE_TURN_ON,
|
|
STATE_OFF,
|
|
STATE_ON,
|
|
Platform,
|
|
)
|
|
from homeassistant.core import HomeAssistant
|
|
from homeassistant.exceptions import HomeAssistantError
|
|
|
|
from . import mock_responses, setup_fronius_integration
|
|
from .test_modbus import GEN24_HYBRID_MODULES, assert_state
|
|
|
|
from tests.common import MockConfigEntry
|
|
from tests.test_util.aiohttp import AiohttpClientMocker
|
|
|
|
POWER_LIMITING = "switch.gen24_storage_ac_power_limiting"
|
|
CHARGE_LIMITING = "switch.gen24_storage_battery_charge_power_limiting"
|
|
DISCHARGE_LIMITING = "switch.gen24_storage_battery_discharge_power_limiting"
|
|
GRID_CHARGING = "switch.gen24_storage_battery_grid_charging"
|
|
|
|
|
|
async def _setup(
|
|
hass: HomeAssistant,
|
|
aioclient_mock: AiohttpClientMocker,
|
|
connection: MockModbusConnection,
|
|
) -> MockConfigEntry:
|
|
connection.for_unit(1).holding.update(
|
|
build_sunspec_map(
|
|
GEN24_HYBRID_MODULES, storage_wcha_max=12800, storage_min_reserve=20.0
|
|
)
|
|
)
|
|
mock_responses(aioclient_mock, fixture_set="gen24_storage")
|
|
with patch("homeassistant.components.fronius.PLATFORMS", [Platform.SWITCH]):
|
|
return await setup_fronius_integration(
|
|
hass, is_logger=False, unique_id="12345678"
|
|
)
|
|
|
|
|
|
async def test_switches_read_from_the_device(
|
|
hass: HomeAssistant,
|
|
aioclient_mock: AiohttpClientMocker,
|
|
mock_fronius_modbus: MockModbusConnection,
|
|
) -> None:
|
|
"""Test the switches show what the inverter reports."""
|
|
await _setup(hass, aioclient_mock, mock_fronius_modbus)
|
|
|
|
for entity_id in (
|
|
POWER_LIMITING,
|
|
CHARGE_LIMITING,
|
|
DISCHARGE_LIMITING,
|
|
GRID_CHARGING,
|
|
):
|
|
assert_state(hass, entity_id, STATE_OFF)
|
|
|
|
|
|
@pytest.mark.parametrize(
|
|
("service", "expected"),
|
|
[(SERVICE_TURN_ON, STATE_ON), (SERVICE_TURN_OFF, STATE_OFF)],
|
|
)
|
|
async def test_toggling_writes_the_register(
|
|
hass: HomeAssistant,
|
|
aioclient_mock: AiohttpClientMocker,
|
|
mock_fronius_modbus: MockModbusConnection,
|
|
service: str,
|
|
expected: str,
|
|
) -> None:
|
|
"""Test toggling a control reaches the device and is read back."""
|
|
await _setup(hass, aioclient_mock, mock_fronius_modbus)
|
|
|
|
await hass.services.async_call(
|
|
SWITCH_DOMAIN, service, {ATTR_ENTITY_ID: GRID_CHARGING}, blocking=True
|
|
)
|
|
await hass.async_block_till_done()
|
|
|
|
assert_state(hass, GRID_CHARGING, expected)
|
|
|
|
|
|
async def test_limit_switches_keep_each_others_mode_bit(
|
|
hass: HomeAssistant,
|
|
aioclient_mock: AiohttpClientMocker,
|
|
mock_fronius_modbus: MockModbusConnection,
|
|
) -> None:
|
|
"""Test the two limit switches share a register without clobbering it.
|
|
|
|
Both live in StorCtl_Mod, so writing one has to merge rather than replace.
|
|
"""
|
|
await _setup(hass, aioclient_mock, mock_fronius_modbus)
|
|
|
|
for entity_id in (CHARGE_LIMITING, DISCHARGE_LIMITING):
|
|
await hass.services.async_call(
|
|
SWITCH_DOMAIN, SERVICE_TURN_ON, {ATTR_ENTITY_ID: entity_id}, blocking=True
|
|
)
|
|
await hass.async_block_till_done()
|
|
|
|
assert_state(hass, CHARGE_LIMITING, STATE_ON)
|
|
assert_state(hass, DISCHARGE_LIMITING, STATE_ON)
|
|
|
|
|
|
async def test_turning_a_limit_on_asserts_its_setpoint(
|
|
hass: HomeAssistant,
|
|
aioclient_mock: AiohttpClientMocker,
|
|
mock_fronius_modbus: MockModbusConnection,
|
|
) -> None:
|
|
"""Test a limit at 100% is an active limit, not a released one.
|
|
|
|
Releasing a limit hands control to the next priority source, which may
|
|
impose one of its own. Holding it at 100% is how that gets overridden.
|
|
"""
|
|
config_entry = await _setup(hass, aioclient_mock, mock_fronius_modbus)
|
|
controls = config_entry.runtime_data.modbus_settings_coordinators[
|
|
0
|
|
].modbus_inverter.controls
|
|
assert controls.power_limit == 100.0
|
|
|
|
await hass.services.async_call(
|
|
SWITCH_DOMAIN, SERVICE_TURN_ON, {ATTR_ENTITY_ID: POWER_LIMITING}, blocking=True
|
|
)
|
|
await hass.async_block_till_done()
|
|
|
|
assert_state(hass, POWER_LIMITING, STATE_ON)
|
|
assert controls.power_limit == 100.0
|
|
|
|
|
|
async def test_a_refused_write_raises(
|
|
hass: HomeAssistant,
|
|
aioclient_mock: AiohttpClientMocker,
|
|
mock_fronius_modbus: MockModbusConnection,
|
|
) -> None:
|
|
"""Test a device rejecting the write surfaces as an error to the user."""
|
|
await _setup(hass, aioclient_mock, mock_fronius_modbus)
|
|
mock_fronius_modbus.for_unit(1).fail_requests(IllegalDataValueError())
|
|
|
|
with pytest.raises(HomeAssistantError, match="Could not write"):
|
|
await hass.services.async_call(
|
|
SWITCH_DOMAIN,
|
|
SERVICE_TURN_ON,
|
|
{ATTR_ENTITY_ID: POWER_LIMITING},
|
|
blocking=True,
|
|
)
|