Add valve platform to Ouman EH-800 (#172149)

This commit is contained in:
Markus Tuominen
2026-05-26 12:22:37 +02:00
committed by GitHub
parent 2d54070cab
commit 71ec3c31fa
7 changed files with 355 additions and 1 deletions
@@ -7,6 +7,7 @@ from .coordinator import OumanEh800ConfigEntry, OumanEh800Coordinator
_PLATFORMS: list[Platform] = [
Platform.SENSOR,
Platform.VALVE,
]
@@ -4,6 +4,7 @@ from datetime import timedelta
import logging
from ouman_eh_800_api import (
ControllableEndpoint,
L1BaseEndpoints,
L2BaseEndpoints,
OumanClientAuthenticationError,
@@ -17,7 +18,11 @@ from ouman_eh_800_api import (
from homeassistant.config_entries import ConfigEntry
from homeassistant.const import CONF_PASSWORD, CONF_URL, CONF_USERNAME
from homeassistant.core import HomeAssistant
from homeassistant.exceptions import ConfigEntryError, ConfigEntryNotReady
from homeassistant.exceptions import (
ConfigEntryError,
ConfigEntryNotReady,
HomeAssistantError,
)
from homeassistant.helpers.aiohttp_client import async_get_clientsession
from homeassistant.helpers.device_registry import DeviceInfo
from homeassistant.helpers.update_coordinator import DataUpdateCoordinator, UpdateFailed
@@ -97,6 +102,21 @@ class OumanEh800Coordinator(DataUpdateCoordinator[dict[OumanEndpoint, OumanValue
except OumanClientCommunicationError as err:
raise UpdateFailed("Error communicating with API") from err
async def async_set_endpoint_value(
self, endpoint: ControllableEndpoint, value: OumanValues | int
) -> None:
"""Set a value on the device and refresh."""
try:
result = await self.client.set_endpoint_value(endpoint, value)
except OumanClientAuthenticationError as err:
raise HomeAssistantError("Authentication failed") from err
except OumanClientCommunicationError as err:
raise HomeAssistantError("Error communicating with API") from err
self.async_set_updated_data({**self.data, endpoint: result})
# Separate refresh on all endpoints to catch cascading changes.
await self.async_request_refresh()
def sync_circuit_device_names(self) -> None:
"""Set the device-reported circuit names for the L1/L2 sub-device names.
@@ -49,6 +49,9 @@
"name": "Supply water temperature setpoint"
},
"valve_position": { "name": "Valve position" }
},
"valve": {
"valve_position_setpoint": { "name": "Valve position setpoint" }
}
}
}
@@ -0,0 +1,83 @@
"""Valve platform for the Ouman EH-800 integration."""
from dataclasses import dataclass
from ouman_eh_800_api import IntControlOumanEndpoint, L1BaseEndpoints, L2BaseEndpoints
from homeassistant.components.valve import (
ValveDeviceClass,
ValveEntity,
ValveEntityDescription,
ValveEntityFeature,
)
from homeassistant.core import HomeAssistant
from homeassistant.helpers.entity_platform import AddConfigEntryEntitiesCallback
from .const import OumanDevice
from .coordinator import OumanEh800ConfigEntry
from .entity import OumanEh800Entity, OumanEh800EntityDescription
PARALLEL_UPDATES = 1
@dataclass(frozen=True, kw_only=True)
class OumanEh800ValveEntityDescription(
OumanEh800EntityDescription, ValveEntityDescription
):
"""Valve description with main/L1/L2 device assignment."""
VALVE_DESCRIPTIONS: dict[IntControlOumanEndpoint, OumanEh800ValveEntityDescription] = {
L1BaseEndpoints.VALVE_POSITION_SETPOINT: OumanEh800ValveEntityDescription(
device=OumanDevice.L1,
key="valve_position_setpoint",
translation_key="valve_position_setpoint",
device_class=ValveDeviceClass.WATER,
),
L2BaseEndpoints.VALVE_POSITION_SETPOINT: OumanEh800ValveEntityDescription(
device=OumanDevice.L2,
key="valve_position_setpoint",
translation_key="valve_position_setpoint",
device_class=ValveDeviceClass.WATER,
),
}
async def async_setup_entry(
hass: HomeAssistant,
entry: OumanEh800ConfigEntry,
async_add_entities: AddConfigEntryEntitiesCallback,
) -> None:
"""Set up Ouman EH-800 valve entities based on a config entry."""
coordinator = entry.runtime_data
async_add_entities(
OumanEh800ValveEntity(coordinator, endpoint, description)
for endpoint in coordinator.data
if isinstance(endpoint, IntControlOumanEndpoint)
and (description := VALVE_DESCRIPTIONS.get(endpoint)) is not None
)
class OumanEh800ValveEntity(OumanEh800Entity, ValveEntity):
"""Ouman EH-800 valve entity."""
entity_description: OumanEh800ValveEntityDescription
_endpoint: IntControlOumanEndpoint
_attr_reports_position = True
_attr_supported_features = (
ValveEntityFeature.SET_POSITION
| ValveEntityFeature.OPEN
| ValveEntityFeature.CLOSE
)
@property
def current_valve_position(self) -> int:
"""Return the current valve position 0-100."""
value = self.coordinator.data[self._endpoint]
assert isinstance(value, float)
return int(value)
async def async_set_valve_position(self, position: int) -> None:
"""Move the valve to the given position."""
await self.coordinator.async_set_endpoint_value(self._endpoint, position)
+15
View File
@@ -236,6 +236,21 @@ def mock_ouman_client(registry_set: OumanRegistrySet) -> Generator[AsyncMock]:
client = mock_client.return_value
client.get_active_registries.return_value = registry_set
client.get_values.return_value = values
# Simulate the device: a successful write changes what subsequent
# reads return, so the coordinator's post-write refresh keeps the
# new value instead of reverting. The API library parses numeric
# responses as floats via ``NumberOumanEndpoint.parse_value``, so
# we mirror that here so int writes round-trip as floats. Tests can
# override by replacing ``set_endpoint_value.side_effect``.
def _set_endpoint_value(
endpoint: OumanEndpoint, value: OumanValues
) -> OumanValues:
stored: OumanValues = float(value) if isinstance(value, int) else value
values[endpoint] = stored
return stored
client.set_endpoint_value.side_effect = _set_endpoint_value
yield client
@@ -0,0 +1,109 @@
# serializer version: 1
# name: test_entities[valve-room_sensors][valve.heating_circuit_1_patterilammitys_valve_position_setpoint-entry]
EntityRegistryEntrySnapshot({
'aliases': list([
None,
]),
'area_id': None,
'capabilities': None,
'config_entry_id': <ANY>,
'config_subentry_id': <ANY>,
'device_class': None,
'device_id': <ANY>,
'disabled_by': None,
'domain': 'valve',
'entity_category': None,
'entity_id': 'valve.heating_circuit_1_patterilammitys_valve_position_setpoint',
'has_entity_name': True,
'hidden_by': None,
'icon': None,
'id': <ANY>,
'labels': set({
}),
'name': None,
'object_id_base': 'Valve position setpoint',
'options': dict({
}),
'original_device_class': <ValveDeviceClass.WATER: 'water'>,
'original_icon': None,
'original_name': 'Valve position setpoint',
'platform': 'ouman_eh_800',
'previous_unique_id': None,
'suggested_object_id': None,
'supported_features': <ValveEntityFeature: 7>,
'translation_key': 'valve_position_setpoint',
'unique_id': '01JABCDEFGHIJKLMNOPQRSTUVW_l1_valve_position_setpoint',
'unit_of_measurement': None,
})
# ---
# name: test_entities[valve-room_sensors][valve.heating_circuit_1_patterilammitys_valve_position_setpoint-state]
StateSnapshot({
'attributes': ReadOnlyDict({
'current_position': 0,
'device_class': 'water',
'friendly_name': 'Heating circuit 1 Patterilämmitys Valve position setpoint',
'is_closed': True,
'supported_features': <ValveEntityFeature: 7>,
}),
'context': <ANY>,
'entity_id': 'valve.heating_circuit_1_patterilammitys_valve_position_setpoint',
'last_changed': <ANY>,
'last_reported': <ANY>,
'last_updated': <ANY>,
'state': 'closed',
})
# ---
# name: test_entities[valve-room_sensors][valve.heating_circuit_2_lattialammitys_valve_position_setpoint-entry]
EntityRegistryEntrySnapshot({
'aliases': list([
None,
]),
'area_id': None,
'capabilities': None,
'config_entry_id': <ANY>,
'config_subentry_id': <ANY>,
'device_class': None,
'device_id': <ANY>,
'disabled_by': None,
'domain': 'valve',
'entity_category': None,
'entity_id': 'valve.heating_circuit_2_lattialammitys_valve_position_setpoint',
'has_entity_name': True,
'hidden_by': None,
'icon': None,
'id': <ANY>,
'labels': set({
}),
'name': None,
'object_id_base': 'Valve position setpoint',
'options': dict({
}),
'original_device_class': <ValveDeviceClass.WATER: 'water'>,
'original_icon': None,
'original_name': 'Valve position setpoint',
'platform': 'ouman_eh_800',
'previous_unique_id': None,
'suggested_object_id': None,
'supported_features': <ValveEntityFeature: 7>,
'translation_key': 'valve_position_setpoint',
'unique_id': '01JABCDEFGHIJKLMNOPQRSTUVW_l2_valve_position_setpoint',
'unit_of_measurement': None,
})
# ---
# name: test_entities[valve-room_sensors][valve.heating_circuit_2_lattialammitys_valve_position_setpoint-state]
StateSnapshot({
'attributes': ReadOnlyDict({
'current_position': 0,
'device_class': 'water',
'friendly_name': 'Heating circuit 2 Lattialämmitys Valve position setpoint',
'is_closed': True,
'supported_features': <ValveEntityFeature: 7>,
}),
'context': <ANY>,
'entity_id': 'valve.heating_circuit_2_lattialammitys_valve_position_setpoint',
'last_changed': <ANY>,
'last_reported': <ANY>,
'last_updated': <ANY>,
'state': 'closed',
})
# ---
+123
View File
@@ -0,0 +1,123 @@
"""Tests for the Ouman EH-800 valve platform."""
from unittest.mock import AsyncMock
from ouman_eh_800_api import (
L1BaseEndpoints,
OumanClientAuthenticationError,
OumanClientCommunicationError,
)
import pytest
from syrupy.assertion import SnapshotAssertion
from homeassistant.components.valve import (
ATTR_POSITION,
DOMAIN as VALVE_DOMAIN,
SERVICE_CLOSE_VALVE,
SERVICE_OPEN_VALVE,
SERVICE_SET_VALVE_POSITION,
)
from homeassistant.const import ATTR_ENTITY_ID, Platform
from homeassistant.core import HomeAssistant
from homeassistant.exceptions import HomeAssistantError
from homeassistant.helpers import entity_registry as er
from tests.common import MockConfigEntry, snapshot_platform
# Only L1 and L2 base endpoints produce valve entities. A single scenario
# that exposes both is enough to cover the snapshot; the relay-only and
# single-circuit scenarios would either be empty or duplicate this output.
@pytest.mark.parametrize("scenario", ["room_sensors"], indirect=True)
@pytest.mark.parametrize("init_integration", [Platform.VALVE], indirect=True)
@pytest.mark.usefixtures("entity_registry_enabled_by_default", "init_integration")
async def test_entities(
hass: HomeAssistant,
snapshot: SnapshotAssertion,
entity_registry: er.EntityRegistry,
mock_config_entry: MockConfigEntry,
) -> None:
"""Test the valve entities for each registry-set scenario."""
await snapshot_platform(hass, entity_registry, snapshot, mock_config_entry.entry_id)
@pytest.mark.parametrize("init_integration", [Platform.VALVE], indirect=True)
@pytest.mark.usefixtures("init_integration")
@pytest.mark.parametrize(
("service", "service_data", "expected_position"),
[
pytest.param(
SERVICE_SET_VALVE_POSITION,
{ATTR_POSITION: 42},
42,
id="set_position",
),
pytest.param(SERVICE_OPEN_VALVE, {}, 100, id="open"),
pytest.param(SERVICE_CLOSE_VALVE, {}, 0, id="close"),
],
)
async def test_async_set_valve_position(
hass: HomeAssistant,
mock_ouman_client: AsyncMock,
service: str,
service_data: dict[str, int],
expected_position: int,
) -> None:
"""Test that valve services write to the device and update state."""
entity_id = "valve.heating_circuit_1_patterilammitys_valve_position_setpoint"
await hass.services.async_call(
VALVE_DOMAIN,
service,
{ATTR_ENTITY_ID: entity_id, **service_data},
blocking=True,
)
mock_ouman_client.set_endpoint_value.assert_called_once_with(
L1BaseEndpoints.VALVE_POSITION_SETPOINT, expected_position
)
assert (
hass.states.get(entity_id).attributes["current_position"] == expected_position
)
@pytest.mark.parametrize("init_integration", [Platform.VALVE], indirect=True)
@pytest.mark.usefixtures("init_integration")
@pytest.mark.parametrize(
("client_error", "expected_message"),
[
pytest.param(
OumanClientAuthenticationError("Wrong username or password"),
"Authentication failed",
id="auth_failure",
),
pytest.param(
OumanClientCommunicationError("Network error: Connection refused"),
"Error communicating with API",
id="communication_failure",
),
],
)
async def test_async_set_valve_position_errors(
hass: HomeAssistant,
mock_ouman_client: AsyncMock,
client_error: Exception,
expected_message: str,
) -> None:
"""Test that client errors are mapped to HomeAssistantError."""
mock_ouman_client.set_endpoint_value.side_effect = client_error
with pytest.raises(HomeAssistantError, match=expected_message):
await hass.services.async_call(
VALVE_DOMAIN,
SERVICE_SET_VALVE_POSITION,
{
ATTR_ENTITY_ID: "valve.heating_circuit_1_patterilammitys_valve_position_setpoint",
ATTR_POSITION: 50,
},
blocking=True,
)
mock_ouman_client.set_endpoint_value.assert_called_once_with(
L1BaseEndpoints.VALVE_POSITION_SETPOINT, 50
)