@@ -336,10 +336,11 @@ def _modbus_mppt_descriptions(
|
||||
|
||||
|
||||
MODBUS_INVERTER_ENTITY_DESCRIPTIONS: list[FroniusSensorEntityDescription] = [
|
||||
# SunSpec model 160 supports up to 4 MPPT modules (GEN24 hybrid, Tauro)
|
||||
# Verto Plus exposes 5 modules (3 PV trackers plus storage charge/discharge),
|
||||
# one more leaves headroom for a hybrid with 4 PV trackers
|
||||
*(
|
||||
description
|
||||
for mppt_no in range(1, 5)
|
||||
for mppt_no in range(1, 7)
|
||||
for description in _modbus_mppt_descriptions(mppt_no)
|
||||
),
|
||||
FroniusSensorEntityDescription(
|
||||
|
||||
@@ -92,6 +92,54 @@ async def test_gen24_storage_mppt(
|
||||
assert len(solar_net.modbus_inverter_coordinators) == 1
|
||||
|
||||
|
||||
@pytest.mark.usefixtures("entity_registry_enabled_by_default")
|
||||
async def test_verto_plus_five_modules(
|
||||
hass: HomeAssistant,
|
||||
aioclient_mock: AiohttpClientMocker,
|
||||
mock_fronius_modbus: MockModbusConnection,
|
||||
) -> None:
|
||||
"""Test a Verto Plus exposing 3 PV trackers plus storage charge/discharge."""
|
||||
mock_fronius_modbus.for_unit(1).holding.update(
|
||||
build_sunspec_map(
|
||||
[
|
||||
MpptModuleSpec(
|
||||
id_str="MPPT 1", current=82, voltage=4021, power=3300, energy=1_000
|
||||
),
|
||||
MpptModuleSpec(
|
||||
id_str="MPPT 2", current=41, voltage=4022, power=1650, energy=2_000
|
||||
),
|
||||
MpptModuleSpec(
|
||||
id_str="MPPT 3", current=20, voltage=4023, power=800, energy=3_000
|
||||
),
|
||||
MpptModuleSpec(
|
||||
id_str="StCha 4", current=0, voltage=0, power=0, energy=4_000
|
||||
),
|
||||
MpptModuleSpec(
|
||||
id_str="StDisCha 5",
|
||||
current=12,
|
||||
voltage=3990,
|
||||
power=480,
|
||||
energy=5_000,
|
||||
),
|
||||
],
|
||||
storage_wcha_max=5000,
|
||||
)
|
||||
)
|
||||
mock_responses(aioclient_mock, fixture_set="gen24_storage")
|
||||
with patch("homeassistant.components.fronius.PLATFORMS", [Platform.SENSOR]):
|
||||
await setup_fronius_integration(hass, is_logger=False, unique_id="12345678")
|
||||
|
||||
assert_state(hass, "sensor.gen24_storage_mppt_3_dc_power", 800)
|
||||
assert_state(hass, "sensor.gen24_storage_mppt_4_dc_power", 0)
|
||||
assert_state(hass, "sensor.gen24_storage_mppt_5_dc_current", 1.2)
|
||||
assert_state(hass, "sensor.gen24_storage_mppt_5_dc_voltage", 399.0)
|
||||
assert_state(hass, "sensor.gen24_storage_mppt_5_dc_power", 480)
|
||||
assert_state(hass, "sensor.gen24_storage_mppt_5_energy", 5000)
|
||||
assert_state(hass, "sensor.gen24_storage_pv_energy_total", 6000)
|
||||
assert_state(hass, "sensor.gen24_storage_battery_charging_energy_total", 4000)
|
||||
assert_state(hass, "sensor.gen24_storage_battery_discharging_energy_total", 5000)
|
||||
|
||||
|
||||